The Problem This Machine Solves

High-volume SMT lines produce 500–2,000+ boards per shift. Every board needs post-reflow cleaning — but the bottleneck isn’t the reflow oven, it’s the cleaning step. Standard batch cleaners clean one board at a time with fixed nozzle positions, creating shadow zones behind tall components and requiring multiple passes to cover the full board. At production volumes, that cycle time adds up: a 15-minute cleaning cycle on a line running 1,000 boards per shift means the cleaner can’t keep up.

Hydro-clean LTS High-Volume Batch PCBA Cleaning Machine

Triangle Spray — Wide Coverage, Fewer Passes

The Hydro-clean LTS uses triangle spray patterns — a nozzle design that creates a wider coverage arc per nozzle pass. Instead of a narrow linear spray that requires multiple sweeps to cover the board, the triangle pattern reaches a broader area in each pass. The result: fewer passes needed to clean the full board, shorter cycle times, and consistent cleaning across boards with mixed component heights.

The double-layer PCB fixture stacks two boards vertically in the cleaning chamber, processing both simultaneously. Combined with the triangle spray’s wider coverage, this gives the LTS the highest throughput in the Hydro-clean family for standard stand-off assemblies.

Key Specifications

Spray Technology Triangle spray — wide coverage pattern, nozzle arm moves left and right
Throughput High — optimized for production volumes; double-layer fixture
PCB Fixture Double-layer — two boards processed simultaneously
Cleaning Capacity Large capacity, mass cleaning
Liquid Pipelines Up to 3 completely independent closed-loop circuits
Chemistry Compatibility Compatible with various chemical media — broad formulation support
Drying Powerful heating and drying system
Shadow Elimination Spray in air without shadow — nozzle arm traverses full width
Rinse Options Double rinse optional
Process Control Visual window; multiple standard and custom fixtures

Control System: Windows OS with touchscreen HMI — programmable recipe storage/recall, cycle data logging, password-protected process parameters, and exportable production records for traceability (IPC-6012, MIL-STD-883, AS9100).

Applications

  • High-volume SMT production — rapid cleaning of standard-profile assemblies at production speed
  • Post-reflow cleaning — flux residue removal on boards exiting the reflow oven
  • Misprint board cleaning — recovering boards with incorrect paste deposits
  • Pallet/tray cleaning — removing contamination from SMT carriers and process pallets
  • Mechanical component cleaning — oil and contamination removal from machined parts
  • Handprint pollution removal — fingerprint and handling contamination from manual assembly stages
  • FOD removal — foreign object debris from board handling and manufacturing
  • Pre-coating cleaning — conformal coating adhesion on high-volume production boards

How It Works

Double-layer loading: Operator loads two boards into the stacked fixture. The triangle spray nozzle arm is positioned to cover both board levels simultaneously.

Wash stage: Heated cleaning chemistry sprayed through the triangle nozzle pattern. The nozzle arm moves left and right across the full board width, ensuring no shadow zones behind tall components. The wider spray arc means each pass covers more area — reducing total passes needed. Chemistry dissolves flux residue, solder paste, and organic contamination.

Rinse stage: DI water rinse removes chemistry and dissolved contaminants. Up to 3 independent liquid pipelines keep wash and rinse circuits completely separated. Optional double rinse adds a second DI water stage for enhanced ionic cleanliness.

Drying stage: Powerful heating system evaporates all moisture from both board levels. The drying system is sized for the double-layer fixture — ensuring both boards dry completely in the same cycle time.

Hydro-clean LTS vs. Alternatives

Feature Hydro-clean LTS Hydro-clean AS Hydro-clean LDS Manual Spray
Spray pattern Triangle — wide coverage Linear direct Linear direct — low stand-off optimized Fixed nozzle
Throughput Highest — double-layer fixture Standard — single board Standard — single board Low
Low stand-off cleaning Good — for standard stand-off Good Best — optimized for 0.05mm Poor
Shadow elimination Traversing nozzle arm — no shadow Linear sweep Linear sweep Shadow zones
Chemistry flexibility Broad — various chemical media Aqueous Aqueous Single chemistry
Pallet/tray cleaning Yes — designed for it Fixture dependent Fixture dependent Manual
Liquid pipelines Up to 3 independent Isolated 3 independent Single

What to Send for a Quote

  1. Board dimensions — maximum length × width × thickness
  2. Component profile — tallest component; lowest stand-off gap
  3. Throughput requirement — boards per hour or shift; confirm double-layer is sufficient
  4. Flux type — rosin, water-soluble, no-clean
  5. Pallet/tray sizes — if also cleaning SMT carriers and process pallets
  6. Cleanliness specification — IPC-6012 class, MIL-STD-2000, or internal spec
  7. Chemistry preference — specific brand or formulation if required

Target Industries

High-volume EMS providers, consumer electronics manufacturing, LED assembly, automotive electronics, industrial controls, power supply manufacturing, any facility running high-throughput SMT lines.

Related Equipment

  • Hydro-clean LDS — linear direct spray optimized for low stand-off packages when BGA/QFN penetration matters more than throughput
  • Hydro-clean AS — automatic PCBA cleaning with AGV integration for automated production lines
  • Hydro-clean ARRAY — inline continuous cleaning for direct integration into SMT production lines